1. QA/QC
1.1. Checklists
2. Weekly Up
3. Clients
3.1. AEP
3.1.1. East
3.1.2. West
3.2. Avangrid
3.2.1. CMP
3.2.2. NYSEG
3.2.3. RG&E
3.2.4. UI
3.3. Entergy
3.4. Eversource
3.4.1. CL&P/WMECO
3.4.2. NSTAR
3.4.3. PSNH
3.5. Excelon
3.5.1. BGE
3.5.2. ComEd
3.5.3. PECO
3.6. Oncor
3.7. Xcel
3.8. ...
4. Equipment
4.1. Major Equipment
4.1.1. Capacitor Banks
4.1.2. Circuit Breakers
4.1.2.1. Interlocks*
4.1.2.1.1. Kirk Key
4.1.3. Circuit Switchers
4.1.4. Current Transformers
4.1.5. Disconnect Switches
4.1.5.1. Motor Operators
4.1.6. Line Traps
4.1.7. Line Tuners
4.1.8. Reactor Banks
4.1.9. Surge Arrestors
4.1.10. Switchgear
4.1.11. Transformers
4.1.12. Voltage Regulators
4.1.13. Voltage Transformers
4.1.13.1. PT/VT
4.1.13.2. CCVT
4.2. Control Houses
4.2.1. AC Panelboards
4.2.2. Batteries
4.2.3. Chargers
4.2.4. Conduits & Fittings*
4.2.5. DC Panelboards
4.2.6. Interior Lighting
4.2.7. Panels
4.3. Commodities
4.3.1. Buswork
4.3.2. Conductors
4.3.2.1. Cable
4.3.2.2. Wire
4.3.2.3. Bare Conductor
4.3.3. Conduits & Fittings*
4.3.4. Earthwork Fill
4.3.5. Electrical Connectors
4.3.6. Erosion Control
4.3.6.1. Crushed Stone
4.3.6.2. Fiber Roll
4.3.6.3. Riprap
4.3.7. Fasteners
4.3.8. Fence
4.3.9. Grounding
4.3.10. Insulators
4.3.11. Raceways
4.3.11.1. Duct Bank
4.3.11.2. Conduit & Fittings*
4.3.12. Structural
4.3.12.1. Aluminum
4.3.12.1.1. Structural
4.3.12.2. Steel
4.3.12.2.1. Structural
4.3.12.2.2. Rebar
4.3.12.3. Concrete
4.4. Protection & Control
4.4.1. Control Switches
4.4.2. Meters
4.4.3. Relays
4.4.4. Carrier
4.5. SCADA & Communication
4.5.1. Data Concentrator
4.5.2. Remote Terminal Unit (RTU)
4.5.3. Networking equipment
4.5.3.1. Router
4.5.3.2. Ethernet Switch
4.5.4. Fiber Optics
5. Station Design
5.1. Civil Design
5.1.1. Access Roads
5.1.2. Foundations
5.1.3. Grading
5.1.4. Storm Water
5.2. Physical Design
5.2.1. Bus Design
5.2.1.1. Rigid Bus Design
5.2.1.2. Strain Bus Design
5.2.2. Connectors
5.2.3. Conductors
5.2.4. Fence
5.2.5. Grounding
5.2.6. Raceways
5.2.6.1. Trench Design
5.2.6.2. Duct Bank Design
5.2.6.3. Conduit & Fittings*
5.2.7. Structures
5.2.7.1. Steel
5.2.7.2. Aluminum
5.2.8. Yard Lighting
5.2.9. Conduit & Fittings*
5.3. Protection & Control Design
5.3.1. IEEE Device Numbers
5.3.2. Relay Instruction Books
5.3.3. Protection Schemes
5.3.3.1. Bus Protection
5.3.3.1.1. High Impedance Differential
5.3.3.1.2. Low Impedance Differential
5.3.3.2. Line Protection
5.3.3.2.1. Pilot (Comm assisted)
5.3.3.2.2. Non-pilot
5.3.3.3. Transformer Protection
5.3.3.3.1. Differential
5.3.3.3.2. Sudden Pressure
5.3.3.4. Breaker Failure Protection
5.3.3.5. Reclosing
5.3.4. SCADA & Communications Design
5.3.4.1. Serial Communications
5.3.4.2. Substation Networks
5.3.4.3. Station Internet Access
5.3.5. Wiring
5.4. Control House Design
5.4.1. AC Panelboard Specification
5.4.2. Battery Charger Specification
5.4.3. Cable Tray Design
5.4.4. DC Panelboard Specification
5.4.5. Substation Battery Bank Sizing
6. Toolbox
6.1. Software
6.1.1. ProjectWise
6.1.2. Bluebeam Revu
6.2. Calculations
6.2.1. Conduit Fill Calculations
6.2.2. Battery Load Calculations
6.2.3. Lightning Protection Studies
6.2.4. Lighting Calculations
6.2.5. Voltage Drop Calculations
6.2.6. ...